title: Resources - Case Studies - GE Healthcare - MobileLink wireless ECG communication
description: GE Healthcare - MobileLink wireless ECG communication
---

[![Silex Technology](https://www.silextechnology.com/hubfs/raw_assets/public/silex/images/logo.svg "Silex Technology")](https://www.silextechnology.com/?hsLang=en-us)

- [Connectivity Solutions](https://www.silextechnology.com/connectivity-solutions)
- [Services](https://www.silextechnology.com/connectivity-solutions/software-services) 
    - [Integration Services](https://www.silextechnology.com/de/software-service/integration-services)
    - [Customization Services](https://www.silextechnology.com/de/software-service/customization-services)
    - [Certification Services](https://www.silextechnology.com/software-service/global-certification-compliance)
- [Applications](https://www.silextechnology.com/application-expertise) 
    - [Medical ](https://www.silextechnology.com/medical)
    - [Transportation & Logistics](https://www.silextechnology.com/application-expertise/transportation-and-logistics)
    - [Factory Automation](https://www.silextechnology.com/application-expertise/factory-automation)
- [Resources](https://www.silextechnology.com/resources) 
    - [Resource Center](https://www.silextechnology.com/resources)
    - [Unwired Blog](https://www.silextechnology.com/unwired)
    - [Support Center](https://www.silextechnology.com/support)
    - [Security Center](https://www.silextechnology.com/security-center)
- [Company](https://www.silextechnology.com/company) 
    - [About Silex](https://www.silextechnology.com/company)
    - [Why Silex](https://www.silextechnology.com/why-silex)
    - [Technology Partnerships](https://www.silextechnology.com/why-silex/partner)
    - [News](https://www.silextechnology.com/unwired/topic/news)
    - [Careers](https://www.silextechnology.com/company/careers)

[ Where to buy ](https://www.silextechnology.com/where-to-purchase?hsLang=en-us)

[ Contact sales ](https://www.silextechnology.com/contact-us?hsLang=en-us)

This is a search field with an auto-suggest feature attached.

- There are no suggestions because the search field is empty.

![Embedded](https://www.silextechnology.com/hubfs/silex/image/Embedded.svg)

[ Embedded Wireless Modules ](https://www.silextechnology.com/connectivity-solutions?services=embedded-wireless-modules&hsLang=en-us)

- [Wi-Fi 7 (802.11be)](https://www.silextechnology.com/connectivity-solutions?services=embedded-wireless-modules&categories=wi-fi-7-80211be)
- [Wi-Fi 6E (802.11ax)](https://www.silextechnology.com/connectivity-solutions?services=embedded-wireless-modules&categories=wi-fi-6e-80211ax)
- [Wi-Fi 6 (802.11ax)](https://www.silextechnology.com/connectivity-solutions?services=embedded-wireless-modules&categories=wi-fi-6-80211ax)
- [Wi-Fi 5 (802.11ac)](https://www.silextechnology.com/connectivity-solutions?services=embedded-wireless-modules&categories=wi-fi-5-80211ac)

![Copy of Product icons home (40 x 40 px) (2)](https://www.silextechnology.com/hubfs/Copy%20of%20Product%20icons%20home%20(40%20x%2040%20px)%20(2).svg)

[ Platform & SOMs ](https://www.silextechnology.com/connectivity-solutions?services=platform--soms&hsLang=en-us)

- [EP-200Q](https://www.silextechnology.com/connectivity-solutions/platform-and-soms/ep-200q)
- [EP-200N](https://www.silextechnology.com/connectivity-solutions-platform-and-som-ep-200n)

![Network System Solutions](https://www.silextechnology.com/hubfs/silex/image/Network%20System.svg)

[ Network System Solutions ](https://www.silextechnology.com/connectivity-solutions?services=network-systems-solutions&hsLang=en-us)

- [Ethernet to Wi-Fi Bridge](https://www.silextechnology.com/connectivity-solutions?services=network-systems-solutions&type=ethernet-to-wi-fi-bridge)
- [USB/Serial Connectivity](https://www.silextechnology.com/connectivity-solutions?services=network-systems-solutions&type=usb-serial-connectivity)
- [Wi-Fi HaLow Connectivity](https://www.silextechnology.com/connectivity-solutions?services=network-systems-solutions&type=wi-fi-halow-connectivity)
- [Wi-Fi Access Points](https://www.silextechnology.com/connectivity-solutions?services=network-systems-solutions&type=wi-fi-access-points)
- [Industrial Connectivity](https://www.silextechnology.com/connectivity-solutions?services=network-systems-solutions&type=industrial-connectivity)
- [Wireless Monitoring](https://www.silextechnology.com/connectivity-solutions?services=network-systems-solutions&type=wireless-monitoring)

#### NEW: EP-200N AMC Edge SoM.

Powered by NXP® i.MX 95, delivering secure, safe and reliable connectivity for industrial and medical applications.

![EP-200N-01](https://www.silextechnology.com/hs-fs/hubfs/EP-200N-01.png?width=100&height=100&name=EP-200N-01.png)

[ Learn more ](https://www.silextechnology.com/connectivity-solutions-platform-and-som-ep-200n?hsLang=en-us)

###### CASE STUDY

# GE Healthcare - MobileLink wireless ECG communication

### Wireless and Secure - MobileLink wireless ECG communication

MobileLink™ is a wireless, integrated ECG communication solution that helps you capture, transmit and analyze your patients’ ECG information with greater speed, efficiency and confidence, thanks to enhanced security protocols. MobileLink is offered as an option to help your staff save steps, reduce errors, expedite report generation and improve charge capture, for better care decisions in less time. By combining all available security protocols into one fortified superset, MobileLink  
can help protect your facility from the risk of transmission interception.

### Enhanced efficiencies

MobileLink facilitates wireless communication between the MAC® 5500/5000 ECG analysis system and the MUSE® ECG Management System, as well as your Hospital Information System (HIS). This seamless integration of patient information helps clinicians improve their workflow and increase efficiencies. 

Error reduction – Data transfers directly from the HIS, through MUSE, to a MAC ECG analysis system – so there’s no manual entry of demographic data and less chance of errors. 

Charge capture – MobileLink sends the information to MUSE, which directly sends the test record to HIS for billing. No delays. No missed charges. No loss of revenue. 

Simplified workflow – Orders are directly downloaded to the Electrocardiograph. After the exam, the ECG data is automatically uploaded to the MUSE, which avoids unnecessary trips to the care unit/heart station and helps increase productivity.

Improved patient care – Previously stored data can be quickly accessed from MUSE, allowing clinicians to perform serial comparisons for more comprehensive studies.

Investment protection – When adding MobileLink to an existing MAC 5500/5000 and current MUSE system, the common interface avoids expensive retraining. MobileLink also adapts easily to changes in your facility’s security protocols. 

Environmentally friendly – The eco-friendly MobileLink is now RoHS compliant.

Service at every step – An experienced team, devoted solely to network design, can assess your current network and review your wireless security measures to help ensure the best results.

### Simplified workflow

 With MobileLink : Reduces manual tasks by 66%, compared to traditional workflows. MobileLink can simplify ECG workflow by helping to prevent mistakes and reduce costs through,

- Seamless integration with the Hospital Information System (HIS) – for consistent charge capture
- Rapid and efficient transfer of ECG and demographic information
- Elimination of patient data re-entry
- Accessibility of ECGs for review and reporting virtually anytime, anywhere![ge2](https://www.silextechnology.com/hs-fs/hubfs/Resources_Images/ge2.png?width=600&height=582&name=ge2.png)

With MobileLink : A traditional ECG workflow is time consuming, and often results in delays, mistakes, misplaced records, unnecessary costs and lost revenues due to, 

- Paper-based orders and reports
- Repetitive manual data entry
- Frequent trips between the patient’s bedside and care unit 
- Lack of physical equipment connections![ge3](https://www.silextechnology.com/hs-fs/hubfs/Resources_Images/ge3.png?width=600&name=ge3.png)

Wireless connectivity between each MAC 5500/5000 and MUSE system places approximately 0.5kb per second or less of traffic on the hospital wired network during data  transfer. Accounting for network protocol overhead, a typical 10kb resting ECG record requires approximately 15-20 seconds to transmit from the MAC 5500/5000 to the MUSE system with MobileLink.

### Security

The MobileLink wireless module includes the following security features:

-  802.1x Extensible Authentication Protocol (EAP) with Transport Layer Security (TLS)
-  Tunneled Transport Layer Security (TTLS)
-  Lightweight Extensible Authentication Protocol (LEAP)
-  Protected Extensible Authentication Protocol (PEAP) or Flexible Authentication via Secure Tunneling (FAST)
-  Open System or Shared Key support with Wired Equivalent Privacy (WEP) encoding
-  WPA (Wi-Fi Protected Access) Personal (WPA-PSK) and Enterprise modes, which utilize improved encryption via the Temporal Key Integrity Protocol (TKIP)
-  WPA2, which adds Advanced Encryption Standard (AES)

### Coexistence

Based on IEEE 802.11b/g standards, the MobileLink option utilizes the Instrument, Scientific, and Medical (ISM) frequency band, operating between 2.400 and 2.485 GHz. This frequency band also supports non-IEEE 802.11b/g wireless standards that are commonly used by medical instrumentation and  wireless PDAs. Compatibility issues can arise when multiple wireless devices share the same frequency band. Coexistence issues, such as partial or complete degradation of bandwidth or transfer rates, can occur. Determination of coexistence issues will require pre-sales consultation by the GE Healthcare ITPS Network Design and Implementation Team.

### System requirements

#### MobileLink

MUSE system at software version 5C.10 or 5D.04 and above, 5E.x, or 7.x, with MobileLink wireless option installed

- IEEE 802.11b/g “Wi-Fi” compliant wireless network
-  A static IP address for each MAC 5500/5000 module
-  Compatible with GE Enterprise Access

#### MobileLink CV Messaging

- MUSE system at software version 5C.10, 5D.04 and above, 5E.x, or 7.x, with MobileLink CV Messaging option installed
- SMTP e-mail server
- E-mail account service must understand MIME or UUENCODED attachments

#### For wireless access through PDA

- GSM wireless network or WiFi for in-hospital
-  Pocket PC with e-mail account service
-  Pocket PC with PDA version of Adobe® Acrobat® Reader®

#### Network requirements

- Pre-quote or post-sales consultation to determine network design and assessment of possible coexistence issues
- All access points installed and tested by customer prior to the network assessment for all necessary areas of coverage
- Hospital IS assistance to provide any necessary security information during the installation. The area of wireless coverage is determined by the spacing and number of access points attached to the network, provided the MUSE has the ability to route to every segment of wireless network in which there will be a MAC 5500/5000 cart. The client bridge can be configured with the IP address of a gateway if the MAC 5500/5000 module is not on the same network as the MUSE system

![ge1](https://www.silextechnology.com/hs-fs/hubfs/Resources_Images/ge1.png?width=733&height=688&name=ge1.png)

### About GE Healthcare

[GE](https://www.gehealthcare.com/) is dedicated to helping you transform healthcare delivery by driving critical breakthroughs in biology and technology. Our expertise in medical imaging and information technologies, medical diagnostics, patient monitoring systems, drug discovery, and biopharmaceutical manufacturing technologies is enabling healthcare professionals around the world to discover new ways to predict, diagnose and treat disease earlier. We call this model of care “Early Health.” The goal: to help clinicians detect disease earlier, access more information and intervene earlier with more targeted treatments, so they can help their patients live their lives to the fullest. Re-think, Re-discover, Re-invent, Re-imagine.

For more information on Silex custom Wi-Fi modules, [contact us](https://www.silextechnology.com/contact-us?hsLang=en-us).

Download the [PDF of this case study.](https://www.silextechnology.com/hubfs/Resource%20PDF/GE-case-study.pdf?hsLang=en-us) 

[![Silex Technology](https://www.silextechnology.com/hubfs/raw_assets/public/silex/images/logo.svg "Silex Technology")](https://www.silextechnology.com/?hsLang=en-us)

### Subscribe to our blog

- [**](https://x.com/silextechnology)
- [**](https://www.linkedin.com/company/silex-technology-america/)
- [**](https://www.youtube.com/user/SilexTechnology)

##### Solutions

- [Embedded Wireless Modules](https://www.silextechnology.com/connectivity-solutions?services=embedded-wireless-modules)
- [Platform & SOMs](https://www.silextechnology.com/connectivity-solutions?services=platform--soms)
- [Network System Solutions](https://www.silextechnology.com/connectivity-solutions?services=network-systems-solutions)
- [Services](https://www.silextechnology.com/connectivity-solutions/software-services)

##### Applications

- [Medical Device Connectivity](https://www.silextechnology.com/application-expertise/medical-devices-learn-more)
- [Transportation & Logistics](https://www.silextechnology.com/de/application-expertise/transportation-and-logistics)
- [Factory Automation](https://www.silextechnology.com/application-expertise/factory-automation)

##### Resources

- [Resource Center](https://www.silextechnology.com/resources)
- [Unwired Blog](https://www.silextechnology.com/unwired)
- [Support Center](https://www.silextechnology.com/support)

##### Company

- [About Silex](https://www.silextechnology.com/company)
- [Why Silex](https://www.silextechnology.com/why-silex)
- [Partnerships](https://www.silextechnology.com/why-silex/partner)
- [News](https://www.silextechnology.com/unwired/topic/news)
- [Careers](https://www.silextechnology.com/company/careers)

##### Contact

- [U.S. Sales](mailto:sales@silexamerica.com)
- [Europe Sales](mailto:sales@silexeurope.com)
- [Customer Support](https://www.silextechnology.com/support/contact-silex-support)

© 2026 Silex Technology America, Inc. [Privacy Policy](https://www.silextechnology.com/contact-us/privacy-policy?hsLang=en-us) [Terms of Use](https://www.silextechnology.com/contact-us/terms-of-use?hsLang=en-us)

![](https://px.ads.linkedin.com/collect/?pid=8007468&fmt=gif)